      SeQuent® Please OTW
      Peripheral drug coated balloon catheter

      SeQuent® Please OTW features an optimized and clinically proven drug-coating technology which facilitates the safe and effective treatment of patients with peripheral arterial disease (PAD) in above and below the knee indications. [1, 2]

      As pioneers and global market leaders in drug-coated balloon catheter technologies that help interventionalists achieve the treatment strategy of leaving (almost) nothing behind, B. Braun brings extensive knowledge to the peripheral field with the SeQuent® Please OTW.

      An effective next generation combination of Paclitaxel and Resveratrol [1,2]

      SeQuent® Please OTW features an optimized and clinically proven drug-coating technology which facilitates the safe and effective treatment of patients with peripheral arterial disease.

      Long-term efficacy with short-term drug release [1,2]

      • Paclitaxel with an effective drug dose of 3μg/mm² [3,4]
      • Significant reduction of TLR and in late lumen loss (LLL) compared to uncoated balloons [1,2,5]

      Resveratrol: A naturally occurring matrix builder

      • Naturally occurring, plant-based substance found for example in the skin of red grapes & raspberries [5]
      • Acts as matrix builder and makes the Paclitaxel bioavailable [5]
      • Enables fast and effective drug transfer into vessel wall [5]

      Mechanically resistant coating (5)

      • Homogeneous coating even in the balloon folds exceeding distal and proximal markers [5]
      • Low drug loss in simulated use [5]
      • Efficient available drug dose at inflation [1,2,5]

      CONSEQUENT Demonstrates Safety and Efficacy

      Safety and efficacy of SeQuent® Please OTW was demonstrated in an unselected, all comers cohort [2] whereas two-year efficacy and safety was shown in the CONSEQUENT RCT [1,4].

      Read more

      References

      [1] Albrecht T et al. Cardiovasc Intervent Radiol. 2018 Jul;41(7):1008-14.
      [2] Langhoff R et al. Angiology. 2021 Mar 29:3319721997314.
      [3] Tepe G et al. N Engl J Med. 2008 Feb 14;358(7):689-99.
      [4] Tepe G et al. Cardiovasc Intervent Radiol. 2017 Oct;40(10):1535-44.
      [5] Data on file at B. Braun.